These capacitors are widely used for resonance coupling, bypassing and feeding circuits in high power radio transmitter, high-frequency tube welding equipment, h.f. quenching stove, h.f. electric stove, h.f. drier, plastic thermally synthesizing machine and wireless communication equipment.

Technical specification

Model Rated Capacitance Rated Voltage (KV) Reactive Power Max. Current Dimensions (mm) Temperature Coefficient
(PF) DC HF(RMS) (KVA) (A) D H A C (PPM/)
CCG11-1 47       68 10 8 9 5 65 90 80 68 +100
100     150
150     220 10 8 20 10 +33
300
680  1000 8 5 10 10 -750
1500
CCG11-2 47      68 8 5 7 4 45 90 60 50 +100
100    150
100    150 8 5 15 8 +33
220
470  1000  5 4 8 8 -750
680  1500
CCG11-3 47     68 4 4 5 5 30 80 52 40 +100
100    150
100    150 4 4 10 5 +33
220
470  1000 3 3 5 5 -750
680  1500
1800
CCG11-4 22  33  47 4 4 2.5 2 30 50 52 40 +100
68     100
47      68  4 4 6 2 +33
100    150
220  330 3 3 4 4 -750
Technical parameters:
1.Typical dissipation factor: ≤0.0008;
2.Volume resistivity: ≥10000MΩ;
3. Permissible variation of rated capacitance: K(+/-10%);
4.Temperature range: -40/+85;
5. Rated temperature: +85℃;
6.Maximum relative humidity: 75%;
7. Test voltage: 2 times of rated voltage if the rated voltage≤15KV or 1.5 times of rated voltage if the rated voltage>15KV.