These capacitors are widely used for resonance coupling, bypassing and feeding circuits in high power radio transmitter, high-frequency tube welding equipment, h.f. quenching stove, h.f. electric stove, h.f. drier, plastic thermally synthesizing machine and wireless communication equipment. |
Technical specification
Model |
Rated Capacitance |
Rated Voltage (KV) |
Reactive Power |
Max. Current |
Dimensions (mm) |
Temperature Coefficient | |||||
(PF) |
DC |
HF(RMS) |
(KVA) |
(A) |
D |
H |
h1 |
h2 |
Copper Nut |
(PPM/ ℃) | |
CCGS-1 |
1000 |
20 |
15 |
2000 |
200 |
110 |
255 |
20 |
105 |
M8 |
-750 |
2000 | |||||||||||
3000 | |||||||||||
CCGS-2 |
2000 |
20 |
15 |
2500 |
250 |
135 |
242 |
22 |
108 |
M8 | |
2500 |
25 |
20 | |||||||||
3000 |
20 |
15 | |||||||||
4000 |
16 |
12 |
218 | ||||||||
5000 |
250 |
128 | |||||||||
5000 |
20 |
15 |
285 |
134 | |||||||
6000 |
16 |
12 |
272 |
134 | |||||||
6000 |
20 |
12 |
320 |
170 | |||||||
CCGS-3 |
4000 |
24 |
20 |
3000 |
250 |
142 |
285 |
25 |
134 |
M8 | |
5000 |
314 | ||||||||||
6000 |
20 |
15 |
320 | ||||||||
CCGS-4 |
5000 |
36 |
30 |
3500 |
300 |
158 |
340 |
30 |
170 |
M10 |
Technical parameters:
1.Typical dissipation factor: ≤0.0008;
2.Volume resistivity: ≥10000MΩ;
3. Permissible variation of rated capacitance: K(+/-10%);
4.Temperature range: -40/+85;
5. Rated temperature: +85℃;
6.Maximum relative humidity: 75%;
7. Test voltage: 2 times of rated voltage if the rated voltage≤15KV or 1.5
times of rated voltage if the rated voltage>15KV.